PCR-LE – Firmware Updater

Firmware Updater

This software is to update the firmware version of the PCR-LE Series.

Ver.

5.07

Last update

2020/11/4

Configuration

  • Applied Products : PCR-LE Series — All models (*PCR-LE2 excluded)
  • Applied Firmware Version : ver2.00 or later
  • Caution: This update file can not used on firmware ver1.99 or earlier. PCR-LE series with firmware ver 1.99 or earlier requires hardware alteration. Contact your kikusui agent or distributor for details.

Notes

  • Confirm the firmware version of the PCR-LE.
    *You can confirm the firmware version by the CONFIG (SHIFT + OPR MODE) > MODEL ID (F5).
  • If any data is stored in the internal memory, save the data to the USB memory before updating the firmware version.
  • The USB memory (up to 16GB) that recognizes the PCR-LE is required for the firmware update
    *To confirm the applicable USB memory : Insert the USB memory to the USB port of the PCR-LE, then check for the display. If the “USB Memory Found” shows on the display, the USB memory can be used for the firmware update. If the USB can not be recognized by the PCR-LE, nothing will be displayed.
  • In a PCR-LE system that uses options such as the three-phase output driver, the firmware of all the PCR-LE units that make up the system must be the same.
  • In case of failure for the installation of firmware version update, please contact your local distributor.

Download

Related Files

Please download the files below.

Firmware update guide

Last update

2013/9/30

Configuration

Adobe Reader

Download

CD image (Operation manual)

Last update

2017/10/19

Download


Firmware update Release Note

VER 5.07
2020-9-09

PCR-LE firmware

Improvement
The protection function when the output voltage range is L range and Vcc is FIXed has been improved.
VER 5.06
2020-3-25

PCR-LE firmware

Resolved issues
When a protection function was activated by the detection of outage, processing to invalidate the output control from SCPI command has been added.
VER 5.05
2020-1-28

PCR-LE firmware

Resolved issues
When the SD021-PCR-LE reconnects communication with the PCR-LE, the problem that setting frequency became the input frequency (50Hz or 60Hz) has been corrected.
VER 5.03
2018-11-22

PCR-LE firmware

Resolved issues
When the SD021-PCR-LE reconnects communication with the PCR-LE, the problem that setting frequency became the input frequency (50Hz or 60Hz) has been corrected.
VER 5.02
2017-10-10

PCR-LE firmware

Resolved issues
The sudden phase change feature of the sequence function has been corrected.
VER 5.01
2017-9-08

PCR-LE firmware

New Feature
The single-phase three-wire/three-phase system (option) feature has been improved. The master-slave parallel operation (option) has been improved. Firmware version 5.xx is not compatible with version 4.xx or earlier. As such, a firmware version check function that runs when a multi-phase operation system or parallel operation system is turned on has been added. If the PCR-LE system contains a mixture of version 5.xx and version 4.xx or earlier versions, “TRBL-22 VERSION ERROR” will occur when the power is turned on.
New Feature
An aperture time setting function has been added. * In conjunction with this addition, the following functions have been changed or deleted. - The measurement update interval of measured values has been changed to aperture time (except line voltage measurements and harmonic current analysis data). - The measurement averaging function has been deleted. - The estimated minimum frequency function has been deleted (a function that was available when an analog signal interface option (EX05-PCR-LE) was installed).
Updated
The soft sensing correction range has been changed from +10% to ±10%.
Updated
Frequencies less than 40 Hz have been excluded from the Soft sensing operation correction range.
Improvement
A function that displays the soft sensing control status on the front panel has been added.
Improvement
The protection function processing that takes place when a sensing wire connection error is detected has been changed. When the protection function is activated, “ALM-22 SENSING FAILURE” will occur. To clear the sensing wire connection error, use alarm clear. * However, depending on the hardware version, the previous error (TRBL-22 SENSING FUSH TRIP) may occur. In this case, the method to clear the sensing wire connection error is the same as before (turn off the power switch and then back on).
VER 4.53
2017-5-22

PCR-LE firmware

Resolved issues
When a sequence is ended in AC+DC mode, the problem of the voltage not being set to the AC voltage specified in the last step due to the peak voltage limit when the preset DC voltage before starting the sequence + the AC voltage waveform’s peak value set in the last step falls outside the -431 V to 431 V range (H range) or -215.5 V to 215.5 V range (L range) has been fixed.
VER 4.52
2016-8-10

PCR-LE firmware

Resolved issues
The problem in which a portion of the output waveform was occasionally different from the voltage settings when a switch was made to a waveform bank containing waveform data with different phases or amplitudes has been fixed.
Resolved issues
The single-phase three-wire/three-phase system (option) feature has been corrected. The problem in which the PCR-LE was initialized to factory default settings when the power supplies of all phases were restarted after only the U-phase unit was turned on and a communication error (TRBL-24:U-V COMM MISS) occurred between the U phase and V phase has been corrected.
VER 4.51
2016-6-17

PCR-LE firmware

Resolved issues
The problem in which a portion of the output voltage waveform was occasionally different from the voltage setting when the frequency setting was changed has been fixed.
Resolved issues
The problem in which the generated peak clipped waveform data being initialized and set to a sine wave when the power switch was turned off and then back on has been fixed.
Resolved issues
The single-phase three-wire/three-phase system (option) feature has been corrected. The problem in which only the V-phase or W-phase waveform data of the arbitrary waveform data set with the SD011-PCR-LE being initialized and set to a sine wave when the power switch was turned off and then back on has been fixed.
VER 4.50
2016-1-15

PCR-LE firmware

New Feature
A voltage surge suppression function setting has been added. A setting for turning off the voltage surge suppression function when the output is turned off has been added.
VER 4.43
2015-11-25
Improvement
The output-off response during Vcc wait times when the internal Vcc voltage is set to auto has been improved.
Resolved issues
The problem of the sequence not changing to the frequency of the next step when frequency "RAMP ON" is specified with the sequence function and the frequencies of the preceding step and the following step are the same has been fixed.
Resolved issues
The single-phase three-wire/three-phase system (option) feature has been corrected. The problem of not being able to set the second parameter (ON/OFF) of PROG:EDIT:PHAS:UV and PROG:EDIT:PHAS:UW (results in a parameter error when this is attempted) has been fixed.
VER 4.42
2015-6-23

PCR-LE firmware

Resolved issues
A problem with the PCR-LE2 500Hz LMT model has been fixed. The problem that remote control settings were initialized when the instrument was power-cycled in order to switch from single-phase-three-wire output to three-phase output,has been fixed.
VER 4.41
2015-5-26

PCR-LE firmware

New Feature
The PCR-LE now returns the installed analog signal interface ("EX05" or "EX06") in response to the communication commands SYST:OPT? and *OPT?.
Resolved issues
Correction to a problem that occurred in master-slave parallel operation (option) and during PCR-LE2 single-phase output. The problem of the QUEStionable status register being cleared immediately when an overcurrent protection was activated has been fixed.
VER 4.40
2015-4-10

PCR-LE firmware

Improvement
The overload protection (ALM-06: OVERLOAD) detection has been improved to accommodate repeated overload conditions. A full scale bar, which indicates that the internal temperature is high, has been added to the load meter. The time (busy state) during which the output cannot be turned on after an ALM-03:OCP occurs has been changed from 10 seconds to 120 seconds. The time (Busy state) during which the output cannot be turned on after an ALM-06:OVERLOAD occurs has been changed from 30 seconds to 120 seconds.
Improvement
An indication of the time until the busy state is cleared (until the output can be turned on) has been added.
Improvement
An indicator that appears when the internal semiconductor protection is activated has been added to the front panel.
Improvement
The maximum used output voltage range (the lower limit) when a fixed internal Vcc is used has been changed. A tracking process in which the maximum used output voltage is kept higher than the peak output voltage has been added.
Improvement
A power unit failure diagnosis at power-on has been added.
Improvement
In AC mode when the voltage settings is at or lower than 10 V (L range) or 20 V (H range), the time that must elapse before the output is turned off when the current limit is exceeded has been changed.
Resolved issues
The single-phase three-wire system (option) has been corrected. Fixed a problem that was preventing panel setting files saved to USB memory devices from being recalled.
Resolved issues
The parameter MAX value for the SYST:CONF:PHAS:UV and SYST:CONF:PHAS:UW communication interface commands has been corrected to 359.
Resolved issues
Fixed a problem that was not resetting the synchronization function to OFF during factory default initialization.
Resolved issues
Fixed the time until ALM-03:OCP is generated after the internal semiconductor protection is activated in DC mode or AC+DC mode.
Resolved issues
Fixed a problem in the peak voltage range check process that is executed when memory is recalled in AC+DC mode.
VER 4.36
2014-11-28

PCR-LE firmware

Improvement
The internal semiconductor protection (OCP) detection has been improved.
Improvement
The reliability in the internal communication of the parallel operation driver (PD05M-PCR-LE/PD05S-PCR-LE) has been improved.
VER 4.34
2014-10-03

PCR-LE firmware

Improvement
A filtering function has been added for the detection of alarm signals.
Resolved issues
A problem that had been occurring when an analog signal interface option (EX05-PCR-LE) was installed has been corrected. A problem with communication interface commands that had been rejected due to "-221 Setting Conflict" errors has been corrected. FUNC:SOUR / SYST:CONF:EXT:SINP:POL / SYST:CONF:EXT:EST:FREQ:LOW
VER 4.33
2014-4-14

PCR-LE firmware

Resolved issues
The output waveform bank could not be changed when the output method was single-phase output. This has been corrected.
Resolved issues
In VER 4.20 to VER4.32, PCR-LE/LE2 memory files saved to USB memory could not be recalled. This has been corrected.
VER 4.32
2014-3-03

PCR-LE firmware

Resolved issues
PCR-LE2 corrections / The selected output method was indicated as single-phase when the output method was changed from single-phase three-wire to three-phase and then the PCR-LE2 was restarted. This has been corrected.
Resolved issues
When phase voltage was specified in single-phase three-wire DC mode, conversion to line voltage could not be carried out. This has been corrected.
Resolved issues
If the output was turned on immediately after a sequence was stopped with the OUTPUT key, the PCR-LE/LE2 was generating the voltage specified before the sequence execution. This has been corrected so that PCR-LE/LE2 generates the voltage at the end of the sequence.
VER 4.31
2014-1-24

PCR-LE firmware

Resolved issues
Depending on the settings, overload protection had been activating even at output less than the rated current. This has been corrected.
Resolved issues
The first soft start after power-on had not been working. This has been corrected.
VER 4.30
2013-11-28

PCR-LE firmware

New Feature
Support for the SD019-PCR-LE/SD020-PCR-LE
Resolved issues
The three-phase system (option) feature has been corrected. In AC+DC mode, W phase could not be selected in the phase selection screen shown on the front panel. This has been corrected.
Resolved issues
A problem that had been occurring when an analog signal interface option (EX05-PCR-LE) was installed has been corrected. The signal source, polarity, and estimated minimum frequency settings had not been backed up. This has been corrected.
VER 4.20
2013-9-19

PCR-LE firmware

Resolved issues
A single-phase three-wire/three-phase system (option) feature has been added. AC+DC mode for multi-phase output
New Feature
Analog signal interface option (EX05-PCR-LE/EX06-PCR-LE) has been added. SHUTDOWN has been added to bit 5 of the QUEStionable status register.
Resolved issues
UVP and OVP judgment in AC+DC mode has been changed to RMS judgment. In conjunction with the change in judgment to RMS values, the OVP and UVP setting ranges have been changed. AC mode / AC+DC mode: 0 to 474.1 V
Resolved issues
The single-phase three-wire/three-phase system (option) feature has been corrected. When trigger input standby and starting phase angle were set in the same step of a sequence, the output waveform of the V phase (W phase) was shifted one step earlier. This has been corrected. If the internal VCC voltage was fixed, there were cases where the output voltages could not be set at once. This has been corrected.
Resolved issues
A problem that occurred when an analog signal interface option (EX05-PCR-LE) was installed in a single-phase three-wire/three-phase system (option) has been corrected. Signal source status display, EXT.OPT menu operation, and EXT.SIG menu display have been corrected.
Resolved issues
Overload was not activated even when the rated current was exceeded when reverse current was in use. This issue has been corrected.
Resolved issues
When a sequence was executed with the internal VCC voltage set to auto, there were cases where the VCC voltage did not change automatically and the output waveform became distorted. This has been corrected.
VER 4.00
2013-4-01

PCR-LE firmware

New Feature
A single-phase three-wire/three-phase system (option) feature has been added. Resistance display of each phase that corresponds to the output impedance setting that ranges from 1 to 100% has been added. U phase offset and phase difference ramp settings have been added to the sequence feature. A U phase offset cancel feature has been added.
VER 3.20
2013-2-01

PCR-LE firmware

Resolved issues
The expression for calculating the measured power factor has been changed from a signed expression to an unsigned expression. (λ=P/S → λ=|P|/S)
Resolved issues
When the power is turned off, the panel’s OUTPUT OFF indication and the output status sometimes did not match. This has been corrected.
VER 3.12
2012-12-10

PCR-LE firmware

Improvement
The reliability in the internal communication of the parallel operation driver (PD05M-PCR-LE/PD05S-PCR-LE) has been improved.
Resolved issues
The load meter full scale calculation when the current limit is set close to the minimum value has been corrected.
VER 3.10
2012-11-12

PCR-LE firmware

Resolved issues
Support for the parallel operation driver option / PD05M-PCR-LE (master) / PD05S-PCR-LE (slave)
Resolved issues
Support for the analog signal interface option / EX05-PCR-LE / EX06-PCR-LE
New Feature
The 2P Mode On/Off function (for selecting the output mode) has been added to the AC mode that uses the single-phase, three-wire output driver option (2P05-PCR-LE).
New Feature
A communication interface command for querying the measured AC power (overall reactive power) has been added. (for the single-phase, three-wire output and three-phase output options) FETCh: POWer:AC:REACtive:TOTal$3 / MEASure:POWer:AC:REACtive:TOTal
Improvement
When panel operation is not possible due to the current condition or conflicts with other settings, the reason is now indicated for better operability.
Resolved issues
The reversed UVP/OVP judgment polarity on the V phase side when the single-phase, three-wire output driver option (2P05-PCR-LE) is in use has been fixed.
Resolved issues
The overload judgment point (threshold) when the frequency is set less than 40 Hz in AC mode has been corrected.
Resolved issues
The error in the calculation of the reactive power of the V and W phases when the single-phase, three-wire output or three-phase output option is in use has been fixed.