This software is to update the firmware version of the PCR-WE/WE2 Series.
Ver.
1.49
Last update
2024/7/2
Configuration
Applicable products: PCR-WE/PCR-WE2 series
Updating is not possible on a parallel operation system. Switch to standalone operation first. Set the rotary switches for the address and the number of slave units on the master unit and all slave units to zero, and then start the update.
[Precautions for parallel operation]
– When mixing PCR-WE and PCR-WEA and operating them in parallel, be sure to set PCR-WE as the master unit.
– PCR-WE requires firmware Ver. 1.47 or later.
– PCR-WEA Ver. 3.x requires firmware Ver. 3.22 or later.
– PCR-WEA Ver. 4.x requires firmware Ver. 4.10 or later.
*The master unit has the following additional conditions.
– PCR-WE requires firmware Ver. 1.48 or later.
– PCR-WEA Ver. 3.x requires firmware Ver. 3.25 or later.
– PCR-WEA Ver. 4.x requires firmware Ver. 4.12 or later.
Notes
Update method
Save the update files (Update.img, CHECKSUM.md5) in the root directory of a USB memory device. Do not change the names of the update files.
Insert the USB memory device containing the update files into the USB port on the front panel. (A USB detected message appears.)
Press EXEC (F5).
Press OK (F4). Do not turn off the main power while the update is in progress. Do not remove the USB memory device.
Turn off the main power of the PCR-WE/WE2, and remove the USB memory device.
Next, check that the firmware has been updated properly.
Firmware version check procedure
Press CONFIG (SHIFT + OPR MODE) > MODEL ID (F5) to display the firmware version.
If Firmware Version 1.xx is displayed on the instrument panel, the update has been completed properly.
If the PCR-WE/PCR-WE2 does not start even if you followed the procedure, if the firmware version is displayed as *1.xx, or if something is unclear, contact your Kikusui agent or Kikusui services (service@kikusui.co.jp).
After the update has been completed properly, reset the PCR-WE/PCR-WE2 to its factory default conditions.
Resolved the following issues regarding the WAVE:DATA:ARB command under specific conditions. brbr- Issue that causes command errors brbr- Issue where the output of the set user-defined waveform is partially different from the setting
Resolved issues
Resolved the issue where the setting ranges of the following limit values are occasionally incorrect after changing the output method settings (three-phase -> single-phase/single-phase three-wire output, single-phase three-wire -> single-phase output). brbr- Upper and lower DC voltage limits brbr- Upper and lower frequency limits
Resolved issues
Resolved the standard of harmonic current analysis function (phase angle) from U-phase current fundamental wave to U-phase voltage fundamental wave.
Resolved issues
Regarding the synchronization function, a problem causing a difference between the frequency value displayed on the screen and the actual output frequency has been fixed.
VER 1.48
2023-4-03
PCR-WE2 firmware
Resolved issues
Fixed the issue where the display updating process of the front panel stops when the sequence function is executed during parallel operation.
VER 1.47
2023-3-10
PCR-WE2 firmware
Resolved issues
Changed the output shutoff process when ALM-02-07:OHP is activated, and the product transitions to protection operation.
VER 1.46
2022-7-07
PCR-WE2 firmware
Resolved issues
Fixed the issue that the screen may transition to the executing screen when a SIM: START RUN command is sent even if the execution conditions of SIM functions are not satisfied.
Resolved issues
Fixed the issue that simulation can be executed even if a voltage exceeding the limit is set for T3 VOLT in the SIM function.
Resolved issues
Fixed the issue of abnormal screen display when setting a value out of range with the PROG:EDIT:JUMP command.
Resolved issues
Fixed the issue that the calibration value may not be written correctly.
Resolved issues
Fixed the issue of falsely detecting [TRBL-03-06 HW Failure] at power-on in very rare cases.
VER 1.45
2021-12-23
PCR-WE2 firmware
Resolved issues
Fixed the issue where OVP occurs under no load condition during sequence operation.
Resolved issues
Fixed the issue of freezing during GPIB communication.
VER 1.44
2021-6-28
PCR-WE2 firmware
Resolved issues
Fixed the issue of analog monitor output malfunction. - Fixed the issue where the gain of other channels changes. - Fixed the issue where the analog monitor settings that were set immediately before are not reproduced.
Resolved issues
Deleted LTLVOLT2 RMS because the rms line voltage item of analog monitor output in the case of single-phase three-wire was duplicated.
Resolved issues
Fixed the issue where the set value may not change when using the encoder in the line voltage setting.
Resolved issues
Fixed the control of the following status registers. STAT:OPER:INST:ENAB, STAT:OPER:INST:ISUM{1|2|3}:ENAB, STAT:QUES:INST:ENAB, STAT:QUES:INST:ISUM{1|2|3}:ENAB
VER 1.43
2021-4-09
PCR-WE2 firmware
Resolved issues
Fixed the issue where normal waveform is not output to the end due to delay of waveform data during parallel operation. [Notes] *When operating in parallel with PCR-WE, it is not compatible with firmware prior to Ver. 1.43. *When operating in parallel with PCR-WEA, firmware Ver. 1.43 or later is required.
VER 1.42
2021-1-30
PCR-WE2 firmware
Improvement
Improved communication control during parallel operation.
Resolved issues
Fixed the issue with updating data in the OPER/QUES status register.
VER 1.41
2020-10-30
PCR-WE2 firmware
Resolved issues
Fixed the issue of falsely detecting OVP of the system.
VER 1.40
2020-7-20
PCR-WE2 firmware
Resolved issues
Fixed the issue where *OPC? cannot correctly acquire the status of measurement completion.
VER 1.38
2020-5-01
PCR-WE2 firmware
Improvement
Improved for compatibility with SD012-PCR-LE/WE.
Resolved issues
Fixed an issue where ALMCLR fails to clear the bit3 (LV) in the QUES resister.
Resolved issues
Fixed the issue of incorrect measured values of the apparent power (AC component) and the power factor (AC components) in the V-phase and W-phase.
VER 1.37
2019-11-28
PCR-WE2 firmware
Resolved issues
Fixed an issue where the UVP alarm condition is not set to the QUES resister.
Resolved issues
Fixed the issue of incorrect display of an elapsed time during power failure simulation.
Resolved issues
Added STEP data error check in sequences executed by the SCPI trigger command, INIT:PROG.
Resolved issues
Fixed the issue of wrong detection of protection operation during termination of sequences in hard sensing.
VER 1.36
2019-11-08
PCR-WE2 firmware
Resolved issues
Changed the output off processing time when voltage surge suppression is on.
Resolved issues
Changed the output timing of the output on status in the function that monitors the operating status.
Resolved issues
Fixed the protection operation processing of sequence execution.
VER 1.33
2019-5-21
PCR-WE2 firmware
Resolved issues
Changed the setting of the one-phase protection function for three-phase operation to 1.2 times the rated current/power.
Strictly Necessary Cookie should be enabled at all times so that we can save your preferences for cookie settings.
If you disable this cookie, we will not be able to save your preferences. This means that every time you visit this website you will need to enable or disable cookies again.
Strictly Necessary Cookie should be enabled at all times so that we can save your preferences for cookie settings.
If you disable this cookie, we will not be able to save your preferences. This means that every time you visit this website you will need to enable or disable cookies again.