PWX Series – IVI-COM Multi-Environment Drivers

未設定メニュー

IVI-COM Multi-Environment Drivers

An IVI-COM multi-environment instrument driver compliant with the IVI specifications. Compatible with Microsoft Office VBA, Visual Basic 6.0, Visual Basic.NET. And because an IVI-C driver is bundled, it is possible to use it easily in LabVIEW and LabWindows/CVI.

Ver.

1.0.4.0

Last update

2012/8/8

Configuration

  • WinXP (x86, SP2 or later)
  • Vista (x86/x64)
  • 7(x86/x64)
  • RS-232C/USB/LAN

Notes

  • To use IVI-COM instrument drivers, a VISA Library that supports VISA COM.
  • We recommend using one of the VISA Libraries supporting VISA COM shown below. (Mind that multiple versions of VISA cannot be installed at a time.)
    • NI-VISA 5.1.0 or later
    • Agilent IO Libraries Suite 16.0 or later
    • KI-VISA 5.0.5 or later
  • When using 32bit OS, the x86 edition of the instrument driver can only be installed.
  • When using 64bit OS, the x64 edition of the instrument driver can only be installed, but it contains the x86 (WOW64) edition.

Download

Common Library / Documents

VISA Libraries
IVI Instrument Driver Programming Guide

  • 2024-04-22 README
    			***********************
    			**** Read Me First ****
    			***********************
    
    Version 1.0.4
    June 17, 2012
    
    
    KikusuiPwx IVI Driver for KIKUSUI PWX series Regulated DC Power Supply
    ---------------------------------------------------------------------------
    
    
    Supported Instruments
    ---------------------
    PWX750L,PWX750ML,PWX750MH,PWX750H,PWX1500L,PWX1500ML,PWX1500MH,PWX1500H,
     
    Installation
    -------------
      System Requirements: The driver installation will check for the
      following requirements.  If not found, the installer will either
      abort, warn, or install the required component as appropriate.
    
      Supported Operating Systems:
        Windows XP
        Windows Vista
        Windows 7
    
      Shared Components
        Before this driver can be installed, your computer must already
        have the IVI Shared Components installed.
    
        The IVI Shared Components installer is available from: 
        http://www.ivifoundation.org/shared_components/Default.aspx
    
    
      VISA-COM
        Any compliant implementation is acceptable. Typically, VISA-COM is
        installed with VISA and other I/O library modules. 
    
    
    Additional Setup
    ----------------
      .NET Framework
        The .NET Framework itself is not required by this driver. If you
        plan to use the driver with .NET, the minimal .NET framework version is 2.0.
    
      The .NET Framework requires an interop assembly for a COM
      server. A Primary Interop Assembly, along with an XML file for
      IntelliSense is installed with the driver. The driver's PIA, along
      with IVI PIAs are installed, by default, in:
      :Program FilesIVI FoundationIVIBinPrimary Interop Assemblies
    
      The PIA is also installed into the Global Assembly Cache (GAC) if
      you have the .NET framework installed.
    
    Help File
    ---------
    
    Revision History
    ----------------
      Version     Date         Notes
      -------   ------------   -----
      0.1.0     Feb 01, 2011  Internal release
      1.0.1     Sep 06, 2011  Public release
      1.0.3     June 07, 2012 Bugfix - IIviDCPwr::CurrentLimit property did acesss native VoltageLevel mistakenly
      1.0.4     June 17, 2012 Bugfix - Simulate mode had bad access to real VISA IO when Initialize, causing app crash
      
    
    IVI Compliance
    --------------
    IVI-COM/IVI-C Specific Instrument Driver
    IVI Instrument Class: IviDCPwr
    
    IviDCPwr Base                   yes
    IviDCPwr Trigger                yes
    
    Optional Features: 
    Interchangeability Checking     no
    State Caching                   yes
    Coercion Recording              no
    
    Driver Identification: 
    Vendor:                         Kikusui
    Description:                    DC Power Supply
    Revision:                       1.0
    Component Identifier:           KikusuiPwx
    
    Hardware Information:
    Instrument Manufacturer:        Kikusui
    Supported Instrument Models:    PWX750L,PWX750ML,PWX750MH,PWX750H,
    Supported Bus Interfaces:       LAN, USB, Serial
    
    32-bit Software Information:
    Supported Operating Systems:    Windows XP/Vista/7
    Support Software Required:      VISA
    Source Code Availability:       Source code included with driver.
    
    64-bit Software Information:
    Supported Operating Systems: 	Windows Vista/7  
    Support Software Required:      VISA
    Source Code Availability:       Source code included with driver.

如有任何问题或担忧,请与我们联系。