Update Module for SD012-PCR-LE/WE (Avionics Test Software)
This is the latest update module for SD012-PCR-LE/WE (Avionics Test Software). To install this module, your PC must already install SD012-PCR-LE/WE (Avionics Test Software).
For data set to the H range, data with voltage below 150V has been corrected to the L range.
Resolved issues
It has been corrected so that in DO-160 16.5.1.8 Voltage Distortion A(CF)&A(NF) and A(WF), the rms value of the waveform file will be the minimum value.
Resolved issues
Fixed a bug that the repeat count was too many by one for all standard tests.
Ver 2.0.0
2022-4-22
Avionics Test Software
New Feature
Added waveform preview screen to main screen and step list.
New Feature
Added "Add" and "Delete" buttons for steps to the step list.
New Feature
Added "Wave" button for steps to the step list, and added a function to create and edit arbitrary waveforms.
New Feature
Added "Output OFF" button to the step list.
New Feature
Added message box display when output is ON.
Ver 1.1.1
2021-4-07
Avionics Test Software
Improvement
Revised the operation guide.
Ver 1.1.0
2020-11-17
Avionics Test Software
New Feature
Added the display of the currently set "output mode" to the main screen.
New Feature
Added "Show message box" to the options.
Resolved issues
Fixed a bug that the previous test conditions were not reflected when the application was restarted immediately after loading the User file.
Ver 1.0.5
2020-3-12
Avionics Test Software
Resolved issues
Added in DO-160F,G 16.5.1.2 because the number of test levels was small.
Resolved issues
In DO-160F,G 16.5.1.3, the test step frequency was half of the standard value, so there was an error in the number of corrections and repetitions.
Resolved issues
There was an error in the repetition of DO-160F, G standard test data.
Resolved issues
In DO-160F,G 16.5.2.3.2, there was an error in the interval time.
Resolved issues
In DO-160F,G 16.5.1.8, the arbitrary waveforms of A (WF) and A (CF) / A (NF) were the same.
Updated
In DO-160G 16.6.1.3b, Table16-3 has changed.
Resolved issues
In DO-160F,G 16.6.1.3c, 16.6.1.3d, 16.5.1.4b, c, d, the interval time was corrected to 10 seconds.
Resolved issues
In DO-160F,G 16.6.1.3d, the setting voltage range was incorrect.
Resolved issues
In DO-160G 16.5.1.4, 16.5.1.4b, 16.5.1.4c, the setting voltage range was incorrect.
Resolved issues
In DO-160F 16.5.1.4c, the setting voltage range was incorrect.
Ver 1.0.4
2019-3-12
Avionics Test Software
New Feature
In this version, test conditions were subdivided for each TestNo.
Ver 1.0.3
2015-4-21
Avionics Test Software
Resolved issues
List of Errors pages were added to Operation Guide.
Ver 1.0.2
2014-7-01
Avionics Test Software
New Feature
In this version, I added function for being able to select all listed tests.
Resolved issues
A Voltage range setting of MIL-STD-704 LDC test data had a problem.
Ver 1.0.1
2014-1-09
Avionics Test Software
Resolved issues
A Loop setting of MIL-STD-704E and F test data had a problem.
Resolved issues
An unnecessary test was included in MIL-STD-704E.
Resolved issues
A Loop setting of DO-160F and G test data had a problem.
Resolved issues
A Loop setting of JIS W0812 test data had a problem.
Ver 1.0.0
2013-8-07
Avionics Test Software
New Feature
The first release.
SD012-PCR-WE (Avionics Test Software)
Ver.
2.01
Last update
2024/5/16
Configuration
Applied Products: SD012-PCR-WE Ver.1.X
Applied Products: SD012-PCR-WE Ver.2.X
Windows 10 (x86/x64)
Windows 11 (x64)
your PC must already install SD012-PCR-WE (Avionics Test Software).
For data set to the H range, data with voltage below 160V has been corrected to the L range.
Resolved issues
It has been corrected so that in DO-160 16.5.1.8 Voltage Distortion A(CF)&A(NF) and A(WF), the rms value of the waveform file will be the minimum value.
Resolved issues
Fixed a bug that the repeat count was too many by one for all standard tests.
Ver 2.0.0
2022-4-22
Avionics Test Software
New Feature
Added waveform preview screen to main screen and step list.
New Feature
Added "Add" and "Delete" buttons for steps to the step list.
New Feature
Added "Wave" button for steps to the step list, and added a function to create and edit arbitrary waveforms.
New Feature
Added "Output OFF" button to the step list.
New Feature
Added message box display when output is ON.
New Feature
Added control of 8kVA single-phase/three-phase output trans "OT03-PCR-WEA".
New Feature
Added voltage correction function.
Ver 1.2.0
2021-4-07
Avionics Test Software
New Feature
Compatible with PCR-WEA series.
Ver 1.1.0
2020-12-17
Avionics Test Software
New Feature
Added the function of "Setting the Wiring Method of the AC Power Supply".
New Feature
Added the display of the currently set "output mode" to the main screen.
New Feature
Added "Show message box" to the options.
Resolved issues
Fixed a bug that the previous test conditions were not reflected when the application was restarted immediately after loading the User file.
Strictly Necessary Cookie should be enabled at all times so that we can save your preferences for cookie settings.
If you disable this cookie, we will not be able to save your preferences. This means that every time you visit this website you will need to enable or disable cookies again.