项目 | PXB20K-50 | PXB20K-250 | PXB20K-500 | PXB20K-1000 | PXB20K-1500 | ||
---|---|---|---|---|---|---|---|
Max 可设定电压 | 52.5 V | 262.5 V | 525 V | 1050 V | 1575 V | ||
设定精度 | ±(0.2 % of setting + 0.1 % of rating) | ||||||
设定分辨率 | 0.005 V | 0.02 V | 0.05 V | 0.1 V | 0.1 V | ||
电源变动 *1 | ±10 mV | ±50 mV | ±100 mV | ±200 mV | ±300 mV | ||
负荷变动 *2 | ±40 mV | ±125 mV | ±250 mV | ±500 mV | ±750 mV | ||
遥控感测 Max 补偿电压(往复) | 10 % of rating | ||||||
内部抵抗設定上限値 | 63 mΩ | 1575 mΩ | 5250 mΩ | 21000 mΩ | 63000 mΩ | ||
内部电阻设定分辨率 | 1 mΩ | 1 mΩ | 1 mΩ | 2 mΩ | 5 mΩ | ||
响应切换 | FAST、SLOW | ||||||
通过速率切换 (TYP) | 12.5 V/ms以上*3 | 62.5 V/ms以上*3 | 125 V/ms以上*3 | 250 V/ms以上*3 | 375 V/ms以上*3 | ||
12.5 V/ms | 62.5 V/ms | 125 V/ms | 250 V/ms | 375 V/ms | |||
1.25 V/ms | 6.25 V/ms | 12.5 V/ms | 25.0 V/ms | 37.5 V/ms | |||
0.125 V/ms | 0.625 V/ms | 1.25 V/ms | 2.50 V/ms | 3.75 V/ms | |||
0.0125 V/ms | 0.0625 V/ms | 0.125 V/ms | 0.250 V/ms | 0.375 V/ms | |||
仅拉电流 *4 | 过渡响应 *5 | 8 ms 以下 | 8 ms 以下 | 8 ms 以下 | 10 ms 以下 | 10 ms 以下 | |
脉动噪声 *6 | p-p*7 | 250 mV | 375 mV | 1000 mV | 1500 mV | 2500 mV | |
rms*8 | 30 mV | 125 mV | 250 mV | 500 mV | 750 mV | ||
上升沿时间 *9 | 全负载 *10 | 10 ms | |||||
无负载 | 10 ms | ||||||
下降沿时间 *11 | 全负载 *10 | 10 ms | |||||
无负载 | 10 ms |
*1. 200Vac 输入时为 180Vac 〜 252Vac、400Vac 输入时为 342Vac 〜 504 Vac。一定负载下。 *2. 额定输出电压下使负载从无负载变化到全负载(额定输出功率/额定输出电压)时的变化量。在感测点进行测量。 *3. 显示屏将显示 MAX。 *4. CV 模式的响应设置为“FAST”时。 *5. 输出电压恢复至额定输出电压 ±(0.1%+10mV) 以内的时间。负载电流的变动值为设定的输出电压下 Max 电流的 50% 〜 100%。 *6. 额定输出电流时。使用 JEITA RC-9131C 探测器,使用 100 :1 探测器测得的值。 *7. 测试频率范围 10Hz 〜 20MHz *8. 测试频率范围 10Hz 〜 1MHz *9. 适用于从额定输出电压的 10% 到 90% 的变化。 *10. 使用纯电阻时 *11. 适用于从额定输出电压的 90% 到 10% 的变化。